Start with a dimension, not the paper size
A scan carries pixels and may carry DPI metadata, but neither proves that the printed part is at model scale. Reduction during printing, photocopying, or PDF export can change the relationship between the border and the geometry. Confirm the CAD drawing unit, select a stated dimension with clear endpoints, and measure that span after placing the image.
For example, if a dimensioned 100 mm span measures 96 drawing units in a millimeter drawing, the uniform correction factor is 100 / 96. Use a reference-based scale operation or the image calibration tool to apply it. Keep the source image untouched so you can revisit the calibration.
Separate scale, rotation, and distortion
A sheet that is merely too large or too small needs uniform scaling. A rotated sheet also needs alignment. Autodesk Raster Design distinguishes Scale, which changes size around a base point, from Match, which uses two source and destination point pairs to move, rotate, and scale an image to vector geometry.
Check a second stated distance far from the first, preferably along a different axis. If one span agrees and another does not, a single scale factor is insufficient. Paper shrinkage or optical distortion can change the horizontal and vertical proportions; Raster Design has a Bias tool for different X and Y corrections. Local warping calls for more careful image correction or manual reconstruction rather than forcing every feature through one global transform.
- Both independent distances wrong by the same ratio: investigate uniform scale and units.
- Distances correct but geometry tilted: correct rotation and alignment.
- Horizontal and vertical errors differ: investigate aspect ratio distortion.
- Errors vary by location: flag local distortion; a single calibration cannot fix the sheet.
Check PDF imports separately
AutoCAD states that PDFIMPORT does not use INSUNITS for an imported PDF page because pages may have different scales. Do not assume the drawing unit setting made the imported content dimensionally correct. Measure a known feature in the actual imported geometry.
Attached raster images can also inherit scale from resolution metadata and insertion settings. Those values are useful for initial placement, not a substitute for dimension-based verification.
Release the calibrated result with evidence
Record the source revision, drawing units, calibration dimension and endpoints, applied factor, and the results of two independent checks. Inspect fit-critical holes or interfaces at full resolution after tracing. If a required dimension is missing or the scan remains distorted, mark the affected geometry as unverified instead of reporting a precision the source cannot support.